In the past, it has been reported that silica glass exposed to gamma radiation exhibits enhanced second-harmonic generation (SHG) when it is thermally poled [1]. More specifically, the second-order nonlinear susceptibility induced by thermal poling was found to increase with an increase in the gamma-ray dose. To explain this effect, it was speculated that radiation-induced defects produce electric dipole moments which are oriented in the direction of the applied electric field during poling and then frozen in the glass when it is cooled to room temperature with the voltage still applied. Although promising, this result has been reported only for type-III silica glass which was irradiated at doses of 10 kGy and 100 kGy. On the other hand, all the poling parameters being identical, type-II silica glass exhibits higher second-order optical nonlinearity than type III silica glass.

In this paper, we report on thermal poling of glass modified by gamma radiation. Type-II silica glass (Herasil) and type-III silica glass (Suprasil) were exposed to gamma-rays from a Cobalt-60 source at high dose rates (6.8 or 9.1 kGy/h) and total doses (119 kGy, 0.8 MGy, 1.5 MGy and 7.1 MGy) and then thermally poled in air at 280 °C, 4 kV for 30 minutes. After poling, SHG in the poled glass samples was investigated using a mode-locked and Q-switched Nd:YAG laser (1064 nm). As a means to study pre-existing and radiation-induced defects, optical absorbance spectra (from ultraviolet to infrared) were measured after irradiation, and also after poling. For each type of silica, a fresh (non-irradiated) sample was poled in the same conditions and taken as a reference.

Second harmonic (SH) intensity in the poled Herasil reference sample was found to be 10 times higher than in the poled Suprasil reference sample, as expected. Depending the type of silica and the dose, the SH intensity in the irradiated samples was either considerably reduced or almost unchanged in comparison with the corresponding reference sample. In none of the samples, including the Suprasil ones, enhancement of SH intensity was observed, in contradiction with [1]. For the Suprasil glass, the SH intensity is reduced by three orders of magnitude in all the irradiated samples but the amount of this decrease depends on total dose and dose rate. For the Herasil glass, the SH intensity is almost unchanged in two samples irradiated at 0.8 MGy and 1.5 MGy while it is reduced by four orders of magnitude in a sample irradiated at 7.1 MGy.

These new and unexpected results on thermal poling of silica glass modified by gamma radiation are important for our understanding of the poling mechanisms, in particular on the aspects related to the role of defects. Actually, absorbance measurements give evidence that glass is significantly modified when it is exposed to high-energy radiation such as gamma rays. The analysis of absorbance spectra also shows that the type of defects and their relative concentrations depend on the type of silica, the dose rate and the total dose. Our results demonstrate that the presence of defects has a strong impact on the SHG induced in the modified glass by thermal poling.
Deparis, O.
6bb2a112-4df2-4902-9645-dd3af9a8cedd
Corbari, C.
0d97e1c1-7a62-47c6-8f97-735f7946f93f
Kazansky, P.G.
a5d123ec-8ea8-408c-8963-4a6d921fd76c
Brichard, B.
b418b620-a207-4ce6-85cd-65ed0a26f891
Berghmans, F.
328b307b-4b5c-4f6f-a4d7-8c5adec346b5
Decreton, M.
9b64b57d-391a-498e-8d88-ce23be64a324
Deparis, O.
6bb2a112-4df2-4902-9645-dd3af9a8cedd
Corbari, C.
0d97e1c1-7a62-47c6-8f97-735f7946f93f
Kazansky, P.G.
a5d123ec-8ea8-408c-8963-4a6d921fd76c
Brichard, B.
b418b620-a207-4ce6-85cd-65ed0a26f891
Berghmans, F.
328b307b-4b5c-4f6f-a4d7-8c5adec346b5
Decreton, M.
9b64b57d-391a-498e-8d88-ce23be64a324

Deparis, O., Corbari, C., Kazansky, P.G., Brichard, B., Berghmans, F. and Decreton, M. (2002) Thermal poling of glass modified by gamma radiation. Fiber-based Component Fab Test and Connectorization (PFO5), Brugge, Belgium. 28 Oct - 01 Nov 2002. (doi:10.1117/12.471969).

Record type: Conference or Workshop Item (Paper)

Abstract

In the past, it has been reported that silica glass exposed to gamma radiation exhibits enhanced second-harmonic generation (SHG) when it is thermally poled [1]. More specifically, the second-order nonlinear susceptibility induced by thermal poling was found to increase with an increase in the gamma-ray dose. To explain this effect, it was speculated that radiation-induced defects produce electric dipole moments which are oriented in the direction of the applied electric field during poling and then frozen in the glass when it is cooled to room temperature with the voltage still applied. Although promising, this result has been reported only for type-III silica glass which was irradiated at doses of 10 kGy and 100 kGy. On the other hand, all the poling parameters being identical, type-II silica glass exhibits higher second-order optical nonlinearity than type III silica glass.

In this paper, we report on thermal poling of glass modified by gamma radiation. Type-II silica glass (Herasil) and type-III silica glass (Suprasil) were exposed to gamma-rays from a Cobalt-60 source at high dose rates (6.8 or 9.1 kGy/h) and total doses (119 kGy, 0.8 MGy, 1.5 MGy and 7.1 MGy) and then thermally poled in air at 280 °C, 4 kV for 30 minutes. After poling, SHG in the poled glass samples was investigated using a mode-locked and Q-switched Nd:YAG laser (1064 nm). As a means to study pre-existing and radiation-induced defects, optical absorbance spectra (from ultraviolet to infrared) were measured after irradiation, and also after poling. For each type of silica, a fresh (non-irradiated) sample was poled in the same conditions and taken as a reference.

Second harmonic (SH) intensity in the poled Herasil reference sample was found to be 10 times higher than in the poled Suprasil reference sample, as expected. Depending the type of silica and the dose, the SH intensity in the irradiated samples was either considerably reduced or almost unchanged in comparison with the corresponding reference sample. In none of the samples, including the Suprasil ones, enhancement of SH intensity was observed, in contradiction with [1]. For the Suprasil glass, the SH intensity is reduced by three orders of magnitude in all the irradiated samples but the amount of this decrease depends on total dose and dose rate. For the Herasil glass, the SH intensity is almost unchanged in two samples irradiated at 0.8 MGy and 1.5 MGy while it is reduced by four orders of magnitude in a sample irradiated at 7.1 MGy.

These new and unexpected results on thermal poling of silica glass modified by gamma radiation are important for our understanding of the poling mechanisms, in particular on the aspects related to the role of defects. Actually, absorbance measurements give evidence that glass is significantly modified when it is exposed to high-energy radiation such as gamma rays. The analysis of absorbance spectra also shows that the type of defects and their relative concentrations depend on the type of silica, the dose rate and the total dose. Our results demonstrate that the presence of defects has a strong impact on the SHG induced in the modified glass by thermal poling.

Text
2446.pdf - Other
Download (140kB)

More information

Published date: 2002
Additional Information: 4934-19
Venue - Dates: Fiber-based Component Fab Test and Connectorization (PFO5), Brugge, Belgium, 2002-10-28 - 2002-11-01

Identifiers

Local EPrints ID: 17026
URI: http://eprints.soton.ac.uk/id/eprint/17026
PURE UUID: dea52606-135e-4b99-9d14-2a18a39f1b4f

Catalogue record

Date deposited: 12 Sep 2005
Last modified: 15 Mar 2024 05:52

Export record

Altmetrics

Contributors

Author: O. Deparis
Author: C. Corbari
Author: P.G. Kazansky
Author: B. Brichard
Author: F. Berghmans
Author: M. Decreton

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×