The University of Southampton
University of Southampton Institutional Repository

The use of the free electron laser source at JLABS for near-IR absorbance measurements of Ga:La:S glasses

The use of the free electron laser source at JLABS for near-IR absorbance measurements of Ga:La:S glasses
The use of the free electron laser source at JLABS for near-IR absorbance measurements of Ga:La:S glasses
Glasses based on gallium and lanthanum sulphides (GLS) have attracted considerable interest over the past few years as they have potential for a range of practical applications. These glasses are among a few systems in which lanthanide compounds appear as a constituent; by partly substituting lanthanum with any other rare earth, optical materials with excellent fluorescence properties are readily obtained. The low phonon energy of the sulphide host reduces the non-radiative quenching of electronic levels with small energy separation to the lower levels; radiative transition rates are high because of the very large refractive index (~2.35 at 1.5µm). Thus, optical transitions are available in GLS that are commonly not observed in the conventional oxide glass hosts, enabling new schemes for fibre lasers and optical amplifiers. The high refractive index of GLS also correlates with high third order nonlinearity, which can be exploited for all-optical switching devices. With their transparency window ranging from about 0.5 to 8µm, GLS glasses are relevant for applications both in the telecom window, and in the mid-IR.

The most challenging part in realising practical devices is the fabrication of single mode optical fibres. While fiberisability of GLS glasses has been demonstrated, optical attenuation in typical GLS fibres is still of the order of dB per meter. This loss, described as partly absorptive and partly due to light scattering, has until now been assumed to be extrinsic, that is, caused by residual impurities, crystals and other defects introduced during the fabrication. However, the bulk loss of GLS has never been adequately measured and even the loss mechanisms are not yet fully understood. Since in other sulphide glass systems the "weak absorption tail" of the electronic absorption edge represents a fundamental limit to the minimum achievable attenuation, the identification and quantification of the loss mechanisms in GLS glass is indispensable.

Measuring the bulk loss in high index optical media is notoriously not an easy task. Thick samples are often not sufficiently homogeneous; on the other hand, the loss over ~centimetre lengths is only less than one hundredth of the Fresnel reflection loss at the sample surfaces, making transmission measurements very troublesome. Besides, these can only provide the total attenuation. Laser calorimetry, on the contrary, is a highly sensitive method to measure directly optical absorption, where a high power laser is directed on a sample placed in a vacuum chamber, and the temperature rise monitored. Analysing samples cut from the same glass batch with different thickness allows discrimination between surface and bulk absorption. The only constraint of the technique is the availability of suitable laser sources at the wavelength of interest. In this respect the Free Electron Laser at the Thomas Jefferson National Accelerator Facility (JLFEL) represents a unique source; when operated on its third harmonic, EEL provides an average power of several hundred watts which can be tuned across the whole near-IR region from the 1 to 2.2 µm.

In this paper we Propose the use of JL-FEL for absolute absorption measurements of GLS glasses in the near-IR window, we discuss in detail the design of the calorimeter and present some preliminary results relative to two different glass compositions.

The authors gratefully acknowledge the team of the Free Electron Laser Program at the Jefferson National Laboratories for their valuable contribution to this work. This work was funded by EPSRC through the grant n. GR/R56372/01.
Petrovich, M.
bfe895a0-da85-4a40-870a-2c7bfc84a4cf
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc
Petrovich, M.
bfe895a0-da85-4a40-870a-2c7bfc84a4cf
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc

Petrovich, M. and Rutt, H.N. (2001) The use of the free electron laser source at JLABS for near-IR absorbance measurements of Ga:La:S glasses. Rank Prize Symposium on Applications of Free Electron Lasers, Grasmere, UK. 17 - 20 Sep 2001.

Record type: Conference or Workshop Item (Paper)

Abstract

Glasses based on gallium and lanthanum sulphides (GLS) have attracted considerable interest over the past few years as they have potential for a range of practical applications. These glasses are among a few systems in which lanthanide compounds appear as a constituent; by partly substituting lanthanum with any other rare earth, optical materials with excellent fluorescence properties are readily obtained. The low phonon energy of the sulphide host reduces the non-radiative quenching of electronic levels with small energy separation to the lower levels; radiative transition rates are high because of the very large refractive index (~2.35 at 1.5µm). Thus, optical transitions are available in GLS that are commonly not observed in the conventional oxide glass hosts, enabling new schemes for fibre lasers and optical amplifiers. The high refractive index of GLS also correlates with high third order nonlinearity, which can be exploited for all-optical switching devices. With their transparency window ranging from about 0.5 to 8µm, GLS glasses are relevant for applications both in the telecom window, and in the mid-IR.

The most challenging part in realising practical devices is the fabrication of single mode optical fibres. While fiberisability of GLS glasses has been demonstrated, optical attenuation in typical GLS fibres is still of the order of dB per meter. This loss, described as partly absorptive and partly due to light scattering, has until now been assumed to be extrinsic, that is, caused by residual impurities, crystals and other defects introduced during the fabrication. However, the bulk loss of GLS has never been adequately measured and even the loss mechanisms are not yet fully understood. Since in other sulphide glass systems the "weak absorption tail" of the electronic absorption edge represents a fundamental limit to the minimum achievable attenuation, the identification and quantification of the loss mechanisms in GLS glass is indispensable.

Measuring the bulk loss in high index optical media is notoriously not an easy task. Thick samples are often not sufficiently homogeneous; on the other hand, the loss over ~centimetre lengths is only less than one hundredth of the Fresnel reflection loss at the sample surfaces, making transmission measurements very troublesome. Besides, these can only provide the total attenuation. Laser calorimetry, on the contrary, is a highly sensitive method to measure directly optical absorption, where a high power laser is directed on a sample placed in a vacuum chamber, and the temperature rise monitored. Analysing samples cut from the same glass batch with different thickness allows discrimination between surface and bulk absorption. The only constraint of the technique is the availability of suitable laser sources at the wavelength of interest. In this respect the Free Electron Laser at the Thomas Jefferson National Accelerator Facility (JLFEL) represents a unique source; when operated on its third harmonic, EEL provides an average power of several hundred watts which can be tuned across the whole near-IR region from the 1 to 2.2 µm.

In this paper we Propose the use of JL-FEL for absolute absorption measurements of GLS glasses in the near-IR window, we discuss in detail the design of the calorimeter and present some preliminary results relative to two different glass compositions.

The authors gratefully acknowledge the team of the Free Electron Laser Program at the Jefferson National Laboratories for their valuable contribution to this work. This work was funded by EPSRC through the grant n. GR/R56372/01.

Text
2377.pdf - Other
Download (95kB)

More information

e-pub ahead of print date: 2001
Venue - Dates: Rank Prize Symposium on Applications of Free Electron Lasers, Grasmere, UK, 2001-09-17 - 2001-09-20

Identifiers

Local EPrints ID: 17102
URI: http://eprints.soton.ac.uk/id/eprint/17102
PURE UUID: 55eac01f-46b7-4ff0-8b17-05a1ede0bd3f
ORCID for M. Petrovich: ORCID iD orcid.org/0000-0002-3905-5901

Catalogue record

Date deposited: 14 Sep 2005
Last modified: 16 Mar 2024 03:16

Export record

Contributors

Author: M. Petrovich ORCID iD
Author: H.N. Rutt

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×